"BaseVoltage": {
"BaseV_115.00000000000001": {
"Ravens.cimObjectType": "BaseVoltage",
"IdentifiedObject.mRID": "2765def0-0fb6-4da2-833e-a7faa659ba4f",
"IdentifiedObject.name": "BaseV_115.00000000000001",
"BaseVoltage.nominalVoltage": 115000.00000000001
}
},
"ConnectivityNode": {
"regbus": {
"Ravens.cimObjectType": "ConnectivityNode",
"IdentifiedObject.mRID": "f4ad543d-0bb8-4fc3-9e58-54022c4904d4",
"IdentifiedObject.name": "regbus",
"ConnectivityNode.OperationalLimitSet": "OperationalLimitSet::'OpLimV_103500.00000000001-126500.00000000003'"
}
},
"PowerSystemResource": {
"Equipment": {
"ConductingEquipment": {
"EnergyConnection": {
"RegulatingCondEq": {
"RotatingMachine": {
"gen1": {
"Ravens.cimObjectType": "SynchronousMachine",
"IdentifiedObject.mRID": "d0c53bdb-4ba4-49cf-8e7f-2f7d6d64fb03",
"IdentifiedObject.name": "gen1",
"RotatingMachine.p": 8000000.0,
"RotatingMachine.q": 0.0,
"RotatingMachine.ratedS": 9600000.0,
"RotatingMachine.ratedU": 12470.0,
"Equipment.inService": true,
"RotatingMachine.ratedPowerFactor": 1.0,
"SynchronousMachine.maxQ": 0.0,
"SynchronousMachine.minQ": -0.0,
"ConductingEquipment.BaseVoltage": "BaseVoltage::'BaseV_115.00000000000001'",
"ConductingEquipment.Terminals": [
{
"Ravens.cimObjectType": "Terminal",
"IdentifiedObject.mRID": "d9353b5e-f062-45a5-bb59-ba02049b6e44",
"IdentifiedObject.name": "gen1_T1",
"ACDCTerminal.sequenceNumber": 1,
"Terminal.phases": "PhaseCode.ABC",
"Terminal.ConnectivityNode": "ConnectivityNode::'regbus'",
"ACDCTerminal.OperationalLimitSet": "OperationalLimitSet::'OpLimV_103500.00000000001-126500.00000000003'"
}
],
"RotatingMachine.GeneratingUnit": {
"Ravens.cimObjectType": "GeneratingUnit",
"IdentifiedObject.mRID": "5a4c1d31-1dc5-4a43-9223-5deb6418df8f",
"IdentifiedObject.name": "gen1_GenUnit",
"GeneratingUnit.minOperatingP": 0.0,
"GeneratingUnit.maxOperatingP": 9600000.0
}
}
}
}
}
}
}
},
"OperationalLimitSet": {
"OpLimV_103500.00000000001-126500.00000000003": {
"Ravens.cimObjectType": "OperationalLimitSet",
"IdentifiedObject.mRID": "c822db31-2e3a-4e95-b1eb-20d13f92d002",
"IdentifiedObject.name": "OpLimV_103500.00000000001-126500.00000000003",
"OperationalLimitSet.OperationalLimitValue": [
{
"Ravens.cimObjectType": "VoltageLimit",
"IdentifiedObject.mRID": "85749b53-4972-4255-a10b-ddfc62e5d57e",
"IdentifiedObject.name": "OpLimV_103500.00000000001-126500.00000000003_RangeAlow",
"VoltageLimit.value": 103500.00000000001,
"VoltageLimit.normalValue": 115000.00000000001,
"OperationalLimit.OperationalLimitType": "OperationalLimitType::'lowType_5000000000.0s'"
},
{
"Ravens.cimObjectType": "VoltageLimit",
"IdentifiedObject.mRID": "6e054ccc-9977-454e-afb5-25ed11131d76",
"IdentifiedObject.name": "OpLimV_103500.00000000001-126500.00000000003_RangeAhigh",
"VoltageLimit.value": 126500.00000000003,
"VoltageLimit.normalValue": 115000.00000000001,
"OperationalLimit.OperationalLimitType": "OperationalLimitType::'highType_5000000000.0s'"
}
]
}
},
"OperationalLimitType": {
"lowType_5000000000.0s": {
"Ravens.cimObjectType": "OperationalLimitType",
"IdentifiedObject.mRID": "d136a61f-cf30-40be-acbe-83640d8c1ae5",
"IdentifiedObject.name": "lowType_5000000000.0s",
"OperationalLimitType.direction": "OperationalLimitDirectionKind.low",
"OperationalLimitType.acceptableDuration": 5000000000.0
},
"highType_5000000000.0s": {
"Ravens.cimObjectType": "OperationalLimitType",
"IdentifiedObject.mRID": "387c871b-b387-4fee-8173-b20a34183ee9",
"IdentifiedObject.name": "highType_5000000000.0s",
"OperationalLimitType.direction": "OperationalLimitDirectionKind.high",
"OperationalLimitType.acceptableDuration": 5000000000.0
}
}
}