WirePositionArray

Type: array

Array of WirePosition objects

No Additional Items

Each item of this array must be:

Type: object

Identification, spacing and configuration of the wires of a conductor with respect to a structure.

No Additional Properties

Type: integer

Numbering for wires on a WireSpacingInfo. Neutrals should be numbered last.

Type: object or number

Signed vertical distance from the wire at this position: above ground (positive value) or burial depth below ground (negative value).

Type: number Default: null

nan

Type: enum (of string) Default: "none"

nan

Must be one of:

  • "f"
  • "c"
  • "G"
  • "d"
  • "z"
  • "p"
  • "y"
  • "h"
  • "Y"
  • "a"
  • "none"
  • "k"
  • "m"
  • "n"
  • "E"
  • "da"
  • "T"
  • "M"
  • "P"
  • "Z"
  • "micro"

Type: enum (of string) Default: "m"

nan

Must be one of:

  • "JPerkg"
  • "NPerm"
  • "WPerW"
  • "JPermol"
  • "WPerm2sr"
  • "V"
  • "A2h"
  • "JPerK"
  • "m3Perkg"
  • "HzPerHz"
  • "T"
  • "Vh"
  • "tonne"
  • "JPerm2"
  • "CPerkg"
  • "VPerHz"
  • "ohm"
  • "K"
  • "m3Compensated"
  • "lx"
  • "lPerh"
  • "APerm"
  • "charPers"
  • "katPerm3"
  • "Pas"
  • "ohmPerm"
  • "radPers2"
  • "Btu"
  • "WPers"
  • "h"
  • "lPerl"
  • "l"
  • "As"
  • "cosPhi"
  • "W"
  • "count"
  • "PaPers"
  • "onePerHz"
  • "m3Pers"
  • "KPers"
  • "Vs"
  • "m2Pers"
  • "Ah"
  • "deg"
  • "mPers2"
  • "lm"
  • "d"
  • "JPerkgK"
  • "m"
  • "min"
  • "dB"
  • "Gy"
  • "Nm"
  • "JPerm3"
  • "sPers"
  • "Q"
  • "rev"
  • "N"
  • "Bq"
  • "WPermK"
  • "GyPers"
  • "HPerm"
  • "molPerkg"
  • "molPerm3"
  • "Wb"
  • "VPerm"
  • "WPerm2"
  • "kn"
  • "CPerm2"
  • "anglemin"
  • "Oe"
  • "kgm"
  • "character"
  • "APerA"
  • "A2s"
  • "Qh"
  • "JPers"
  • "Hz"
  • "rad"
  • "kat"
  • "degC"
  • "bar"
  • "M"
  • "molPermol"
  • "kgPerJ"
  • "J"
  • "HzPers"
  • "WPersr"
  • "anglesec"
  • "F"
  • "Mx"
  • "ha"
  • "SPerm"
  • "gal"
  • "mmHg"
  • "m2"
  • "mPers"
  • "V2h"
  • "m3"
  • "G"
  • "H"
  • "mol"
  • "rotPers"
  • "VAh"
  • "mPerm3"
  • "onePerm"
  • "V2"
  • "WPerA"
  • "Pa"
  • "kgPerm3"
  • "CPerm3"
  • "Sv"
  • "S"
  • "JPermolK"
  • "ft3"
  • "Wh"
  • "radPers"
  • "ohmm"
  • "kgm2"
  • "m3Perh"
  • "dBm"
  • "VA"
  • "A2"
  • "s"
  • "therm"
  • "VArh"
  • "cd"
  • "VPerV"
  • "gPerg"
  • "kg"
  • "A"
  • "m3Uncompensated"
  • "ppm"
  • "FPerm"
  • "C"
  • "sr"
  • "none"
  • "VPerVAr"
  • "VAr"
  • "VPerVA"
  • "lPers"

Type: object or number

Signed horizontal distance from the wire at this position to a common reference point.

Same definition as WirePosition.yCoord

Type: string

Used in RAVENS Schema to identify the corresponding CIM Object Type of the JSON object.

Type: string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

Type: string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy.
The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

Type: string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

Type: string

The name is any free human readable and possibly non unique text naming the object.