Tangible resource of the utility, including power system equipment, various end devices, cabinets, buildings, etc. For electrical network equipment, the role of the asset is defined through PowerSystemResource and its subclasses, defined mainly in the Wires model (refer to IEC61970-301 and model package IEC61970::Wires). Asset description places emphasis on the physical characteristics of the equipment fulfilling that role.
No Additional PropertiesTrue if weeds are to be removed around asset.
If true, there is no physical device. As an example, a virtual meter can be defined to aggregate the consumption for two or more physical meters. Otherwise, this is a physical hardware device.
Visible height of structure above ground level for overhead construction (e.g., Pole or Tower) or below ground level for an underground vault, manhole, etc. Refer to associated DimensionPropertiesInfo for other types of dimensions.
No Additional Propertiesnan
nan
nan
True if a block of material has been attached to base of pole in ground for stability. This technique is used primarily when anchors can not be used.
Automated meter reading (AMR) system communicating with this com module.
Direction of this support structure.
No Additional Propertiesnan
nan
nan
(if anchor) Number of rods used.
Date fumigant was last applied.
Number of circuits in duct bank. Refer to associations between a duct (ConductorAsset) and an ACLineSegment to understand which circuits are in which ducts.
Used in RAVENS Schema to identify the corresponding CIM Object Type of the JSON object.
Name of fumigant.
Kind of structure support.
Time zone offset relative to GMT for the location of this com module.
No Additional Propertiesnan
nan
nan
Time zone offset relative to GMT for the location of this end device.
No Additional Propertiesnan
nan
nan
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.
Construction structure on the tower.
If true, this is a premises area network (PAN) device.
Configuration of joint.
Material this structure is made of.
Size of this support structure.
Diameter of the pole.
No Additional Propertiesnan
nan
nan
Meter form designation per ANSI C12.10 or other applicable standard. An alphanumeric designation denoting the circuit arrangement for which the meter is applicable and its specific terminal arrangement.
Automated meter reading (AMR) or other communication system responsible for communications to this end device.
Maximum rated voltage of the equipment that can be mounted on/contained within the structure.
No Additional Propertiesnan
nan
nan
The framing structure mounted on the pole.
(if anchor) Kind of anchor.
Kind of treatment for this pole.
Pole class: 1, 2, 3, 4, 5, 6, 7, H1, H2, Other, Unknown.
Kind of usage of the vehicle.
(if anchor) Length of rod used.
No Additional Propertiesnan
nan
nan
Joint pole agreement reference number.
Length of the pole (inclusive of any section of the pole that may be underground post-installation).
No Additional Propertiesnan
nan
nan
Installation code.
The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy.
The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.
Material used to fill the joint.
Date weed were last removed.
Kind of FACTS device.
Power rating of light.
No Additional Propertiesnan
nan
nan
Lamp kind.
Date sealing warranty expires.
Date and time pole was last treated with preservative.
The name is any free human readable and possibly non unique text naming the object.
Kind of this facility.
Pole species. Aluminum, Aluminum Davit, Concrete, Fiberglass, Galvanized Davit, Galvanized, Steel Davit Primed, Steel Davit, Steel Standard Primed, Steel, Truncated, Wood-Treated, Wood-Hard, Wood-Salt Treated, Wood-Soft, Wood, Other, Unknown.
If true, there is a communicating inverter present.
A code used to specify the connection category, e.g. low voltage, where the meter operates.
If true, autonomous daylight saving time (DST) function is supported.
(if applicable) Date the tool was last calibrated.
Length of arm. Note that a new light may be placed on an existing arm.
No Additional Propertiesnan
nan
nan
Kind of base for this pole.
Length of this support structure.
No Additional Propertiesnan
nan
nan
True if vault is ventilating.
True if vault is ventilating.
The type of insulation around the joint, classified according to the utility's asset management standards and practices.
Kind of preservative for this pole.
Date and time the last odometer reading was recorded.
Odometer reading of this vehicle as of the 'odometerReadingDateTime'. Refer to associated ActivityRecords for earlier readings.
No Additional Propertiesnan
nan
nan
Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.
Primary material of underground structure.