WireInfo

Type: object

Wire data that can be specified per line segment phase, or for the line segment as a whole in case its phases all have the same wire characteristics.

Type: object

Overhead wire data.

Type: array

Information on a wire carrying a single phase.

No Additional Items

Each item of this array must be:

Type: object

Information on a wire carrying a single phase.

Type: enum (of string)

Phase information.

Must be one of:

  • "A"
  • "B"
  • "C"
  • "N"
  • "s1"
  • "s2"

Type: string

Describes the wire gauge or cross section (e.g., 4/0, #2, 336.5).

Type: object or number

(if insulated conductor) Thickness of the insulation.

Type: enum (of string) Default: "none"

nan

Must be one of:

  • "p"
  • "n"
  • "micro"
  • "m"
  • "c"
  • "d"
  • "k"
  • "M"
  • "G"
  • "T"
  • "none"
  • "y"
  • "z"
  • "a"
  • "f"
  • "da"
  • "h"
  • "P"
  • "E"
  • "Z"
  • "Y"

Type: enum (of string) Default: "m"

nan

Must be one of:

  • "none"
  • "m"
  • "kg"
  • "s"
  • "A"
  • "K"
  • "mol"
  • "cd"
  • "deg"
  • "rad"
  • "sr"
  • "Gy"
  • "Bq"
  • "degC"
  • "Sv"
  • "F"
  • "C"
  • "S"
  • "H"
  • "V"
  • "ohm"
  • "J"
  • "N"
  • "Hz"
  • "lx"
  • "lm"
  • "Wb"
  • "T"
  • "W"
  • "Pa"
  • "m2"
  • "m3"
  • "mPers"
  • "mPers2"
  • "m3Pers"
  • "mPerm3"
  • "kgm"
  • "kgPerm3"
  • "WPermK"
  • "JPerK"
  • "ppm"
  • "rotPers"
  • "radPers"
  • "VA"
  • "VAr"
  • "cosPhi"
  • "Vs"
  • "V2"
  • "As"
  • "A2"
  • "A2s"
  • "VAh"
  • "Wh"
  • "VArh"
  • "VPerHz"
  • "HzPers"
  • "character"
  • "charPers"
  • "kgm2"
  • "dB"
  • "WPers"
  • "lPers"
  • "dBm"
  • "h"
  • "min"
  • "Q"
  • "Qh"
  • "ohmm"
  • "APerm"
  • "V2h"
  • "A2h"
  • "Ah"
  • "count"
  • "ft3"
  • "m3Perh"
  • "gal"
  • "Btu"
  • "l"
  • "lPerh"
  • "lPerl"
  • "gPerg"
  • "molPerm3"
  • "molPermol"
  • "molPerkg"
  • "sPers"
  • "HzPerHz"
  • "VPerV"
  • "APerA"
  • "VPerVA"
  • "rev"
  • "kat"
  • "JPerkg"
  • "m3Uncompensated"
  • "m3Compensated"
  • "WPerW"
  • "therm"
  • "onePerm"
  • "m3Perkg"
  • "Pas"
  • "Nm"
  • "NPerm"
  • "radPers2"
  • "WPerm2"
  • "JPerkgK"
  • "JPerm3"
  • "VPerm"
  • "CPerm3"
  • "CPerm2"
  • "FPerm"
  • "HPerm"
  • "JPermol"
  • "JPermolK"
  • "CPerkg"
  • "GyPers"
  • "WPersr"
  • "WPerm2sr"
  • "katPerm3"
  • "d"
  • "anglemin"
  • "anglesec"
  • "ha"
  • "tonne"
  • "bar"
  • "mmHg"
  • "M"
  • "kn"
  • "Vh"
  • "Mx"
  • "G"
  • "Oe"
  • "WPerA"
  • "SPerm"
  • "onePerHz"
  • "VPerVAr"
  • "ohmPerm"
  • "kgPerJ"
  • "JPers"
  • "m2Pers"
  • "JPerm2"
  • "KPers"
  • "PaPers"

Type: number Default: null

nan

Type: integer

(if used) Number of strands in the steel core.

Type: object or number

Current carrying capacity of the wire under stated thermal conditions.

Type: enum (of string) Default: "none"

nan

Same definition as multiplier

Type: enum (of string) Default: "A"

nan

Same definition as unit

Type: number Default: null

nan

Type: object or number

Outside radius of the wire.

Same definition as WireInfo.insulationThickness

Type: string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

Type: enum (of string)

Conductor material.

Must be one of:

  • "aluminumAlloy"
  • "aaac"
  • "aluminumSteel"
  • "aluminum"
  • "copper"
  • "aluminumAlloySteel"
  • "other"
  • "acsr"
  • "steel"

Type: object or number

DC resistance per unit length of the conductor at 20 °C.

Type: enum (of string) Default: "none"

nan

Same definition as multiplier

Type: enum (of string) Default: "ohmPerm"

nan

Same definition as unit

Type: number Default: null

nan

Type: object or number

AC resistance per unit length of the conductor at 50 °C.

Same definition as WireInfo.rDC20

Type: object or number

(if there is a different core material) Radius of the central core.

Same definition as WireInfo.insulationThickness

Type: enum (of string)

(if insulated conductor) Material used for insulation.

Must be one of:

  • "highMolecularWeightPolyethylene"
  • "asbestosAndVarnishedCambric"
  • "ethylenePropyleneRubber"
  • "varnishedDacronGlass"
  • "lowCapacitanceRubber"
  • "beltedPilc"
  • "oilPaper"
  • "other"
  • "crosslinkedPolyethylene"
  • "unbeltedPilc"
  • "ozoneResistantRubber"
  • "butyl"
  • "rubber"
  • "varnishedCambricCloth"
  • "treeRetardantCrosslinkedPolyethylene"
  • "siliconRubber"
  • "highPressureFluidFilled"
  • "treeResistantHighMolecularWeightPolyethylene"

Type: string

The name is any free human readable and possibly non unique text naming the object.

Type: integer

Number of strands in the conductor.

Type: object or number

AC resistance per unit length of the conductor at 75 °C.

Same definition as WireInfo.rDC20

Type: object or number

AC resistance per unit length of the conductor at 25 °C.

Same definition as WireInfo.rDC20

Type: object or number

Geometric mean radius. If we replace the conductor by a thin walled tube of radius GMR, then its reactance is identical to the reactance of the actual conductor.

Same definition as WireInfo.insulationThickness

Type: string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy.
The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

Type: string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

Type: boolean

True if conductor is insulated.

Type: object

Cable data.

Type: object

Tape shield cable data.

Type: boolean

True if wire strands are extruded in a way to fill the voids in the cable.

Type: string

Describes the wire gauge or cross section (e.g., 4/0, #2, 336.5).

Type: object or number

(if insulated conductor) Thickness of the insulation.

Same definition as WireInfo.insulationThickness

Type: integer

(if used) Number of strands in the steel core.

Type: object or number

Current carrying capacity of the wire under stated thermal conditions.

Same definition as WireInfo.ratedCurrent

Type: string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

Type: boolean

True if conductor is insulated.

Type: enum (of string)

Kind of outer jacket of this cable.

Must be one of:

  • "insulating"
  • "linearLowDensityPolyethylene"
  • "none"
  • "other"
  • "semiconducting"
  • "pvc"
  • "polyethylene"

Type: object or number

Maximum nominal design operating temperature.

Type: object or number

Percentage of the tape shield width that overlaps in each wrap, typically 10% to 25%.

Type: number Default: null

Normally 0 to 100 on a defined base.

Type: object or number

Diameter over the core, including any semi-con screen; should be the insulating layer's inside diameter.

Same definition as WireInfo.insulationThickness

Type: object or number

DC resistance per unit length of the conductor at 20 °C.

Same definition as WireInfo.rDC20

Type: object or number

AC resistance per unit length of the conductor at 50 °C.

Same definition as WireInfo.rDC20

Type: object or number

(if there is a different core material) Radius of the central core.

Same definition as WireInfo.insulationThickness

Type: enum (of string)

(if insulated conductor) Material used for insulation.

Same definition as WireInfo.insulationMaterial

Type: object or number

Diameter over the outermost jacketing layer.

Same definition as WireInfo.insulationThickness

Type: boolean

True if sheath / shield is used as a neutral (i.e., bonded).

Type: enum (of string)

Material of the shield.

Must be one of:

  • "copper"
  • "steel"
  • "aluminum"
  • "lead"
  • "other"

Type: integer

Number of strands in the conductor.

Type: object or number

AC resistance per unit length of the conductor at 75 °C.

Same definition as WireInfo.rDC20

Type: object or number

Diameter over the insulating layer, excluding outer screen.

Same definition as WireInfo.insulationThickness

Type: enum (of string)

Kind of construction of this cable.

Must be one of:

  • "compacted"
  • "other"
  • "segmental"
  • "compressed"
  • "sector"
  • "solid"
  • "stranded"

Type: object or number

Thickness of the tape shield, before wrapping.

Same definition as WireInfo.insulationThickness

Type: object or number

Diameter over the outer screen; should be the shield's inside diameter.

Same definition as WireInfo.insulationThickness

Type: object or number

AC resistance per unit length of the conductor at 25 °C.

Same definition as WireInfo.rDC20

Type: object or number

Geometric mean radius. If we replace the conductor by a thin walled tube of radius GMR, then its reactance is identical to the reactance of the actual conductor.

Same definition as WireInfo.insulationThickness

Type: string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy.
The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

Type: string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

Type: string

The name is any free human readable and possibly non unique text naming the object.

Type: object

Concentric neutral cable data.

Type: boolean

True if wire strands are extruded in a way to fill the voids in the cable.

Type: string

Describes the wire gauge or cross section (e.g., 4/0, #2, 336.5).

Type: object or number

(if insulated conductor) Thickness of the insulation.

Same definition as WireInfo.insulationThickness

Type: integer

Number of concentric neutral strands.

Type: integer

(if used) Number of strands in the steel core.

Type: object or number

Current carrying capacity of the wire under stated thermal conditions.

Same definition as WireInfo.ratedCurrent

Type: string

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy.

Type: boolean

True if conductor is insulated.

Type: object or number

Maximum nominal design operating temperature.

Same definition as CableInfo.nominalTemperature

Type: object or number

DC resistance per unit length of the conductor at 20 °C.

Same definition as WireInfo.rDC20

Type: object or number

Diameter over the core, including any semi-con screen; should be the insulating layer's inside diameter.

Same definition as WireInfo.insulationThickness

Type: object or number

AC resistance per unit length of the conductor at 50 °C.

Same definition as WireInfo.rDC20

Type: object or number

(if there is a different core material) Radius of the central core.

Same definition as WireInfo.insulationThickness

Type: enum (of string)

(if insulated conductor) Material used for insulation.

Same definition as WireInfo.insulationMaterial

Type: object or number

Diameter over the outermost jacketing layer.

Same definition as WireInfo.insulationThickness

Type: boolean

True if sheath / shield is used as a neutral (i.e., bonded).

Type: integer

Number of strands in the conductor.

Type: object or number

AC resistance per unit length of the conductor at 75 °C.

Same definition as WireInfo.rDC20

Type: object or number

DC resistance per unit length of the neutral strand at 20 °C.

Same definition as WireInfo.rDC20

Type: object or number

Diameter over the insulating layer, excluding outer screen.

Same definition as WireInfo.insulationThickness

Type: object or number

Diameter over the outer screen; should be the shield's inside diameter.

Same definition as WireInfo.insulationThickness

Type: object or number

AC resistance per unit length of the conductor at 25 °C.

Same definition as WireInfo.rDC20

Type: object or number

Geometric mean radius. If we replace the conductor by a thin walled tube of radius GMR, then its reactance is identical to the reactance of the actual conductor.

Same definition as WireInfo.insulationThickness

Type: string

The aliasName is free text human readable name of the object alternative to IdentifiedObject.name. It may be non unique and may not correlate to a naming hierarchy.
The attribute aliasName is retained because of backwards compatibility between CIM relases. It is however recommended to replace aliasName with the Name class as aliasName is planned for retirement at a future time.

Type: string

Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended.
For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements.

Type: string

The name is any free human readable and possibly non unique text naming the object.